A new mixed mode solid phase extraction strategy for opioids, cocaines, amphetamines and adulterants in human blood with hybrid liquid chromatography tandem mass spectrometry detection

Geraldine Dowling, Liam Regan

Research output: Contribution to journalArticlepeer-review

38 Citations (Scopus)

Abstract

A rapid method has been developed to analyse morphine, codeine, 6-monoacetylmorphine, cocaine, benzoylecgonine, dihydrocodeine, cocaethylene, 3,4-methylenedioxyamphetamine, ketamine, 3,4-methylenedioxymethamphetamine, pseudoephedrine, lignocaine, benzylpiperazine, methamphetamine, amphetamine, methadone, phenethylamine and levamisole in human blood. Blood samples were cleaned up using mixed mode solid phase extraction using Evolute™ CX solid phase extraction cartridges and the sample aliquots were analysed by hybrid triple quadrupole linear ion trap (QTRAP) mass spectrometry with a runtime of 12.5. min. Multiple reaction monitoring (MRM) as survey scan and an enhanced product ion (EPI) scan as dependent scan were performed in an information-dependent acquisition (IDA) experiment. Finally, drug identification and confirmation was carried out by library search with a developed in-house MS/MS library based on EPI spectra at a collision energy spread of 35 ± 15 in positive mode and MRM ratios. The method was validated in blood, according to the criteria defined in Commission Decision 2002/657/EC. At least two MRM transitions for each substance were monitored in addition to EPI spectra. Deuterated analogues of analytes were used as internal standards for quantitation where possible. The method proved to be simple and time efficient and was implemented as an analytical strategy for the illicit drug monitoring of opioids, cocaines, amphetamines and adulterants in forensic cases of crime offenders, abusers or victims in the Republic of Ireland.

Original languageEnglish
Pages (from-to)1136-1145
Number of pages10
JournalJournal of Pharmaceutical and Biomedical Analysis
Volume54
Issue number5
DOIs
Publication statusPublished - 5 Apr 2011
Externally publishedYes

Keywords

  • Drugs of abuse
  • Human blood
  • Liquid chromatography hybrid triple quadrupole linear ion trap (QTRAP) mass spectrometry
  • Method validation
  • Solid phase extraction