T1 - Air-displacement plethysmography
T2 - Here to stay
AU - Fields, David A.
AU - Higgins, Paul B.
AU - Radley, Duncan
PY - 2005/11
Y1 - 2005/11
N2 - Purpose of review: Air-displacement plethysmography holds promise as an alternative to more traditional body composition techniques, although our understanding of air-displacement plethysmography is less than complete, Specifically, factors that influence its validity and application in certain populations, for example children, the obese, and athletes, must be better understood. This review will summarize recent findings on the validity and precision of air-displacement plethysmography and will focus primarily on papers published since 2004, with particular attention on its use in infants. Recent findings: The most significant recent findings in the air-displacement plethysmography literature are mechanistic in nature specifically dealing with measurement issues such as heat, moisture, clothing, and recently, inter-device variability. Summary: It is important to recognize that air-displacement plethysmography can be a practical instrument in the evaluation of body composition in a wide range of populations. Therefore, based on the body of literature that has emerged, air-displacement plethysmography appears to be a suitable and reliable instrument in the assessment of body composition. Of particular interest is its use in pediatric and obese individuals, areas requiring further study. Research is also needed to help us better understand sources of measurement error.
AB - Purpose of review: Air-displacement plethysmography holds promise as an alternative to more traditional body composition techniques, although our understanding of air-displacement plethysmography is less than complete, Specifically, factors that influence its validity and application in certain populations, for example children, the obese, and athletes, must be better understood. This review will summarize recent findings on the validity and precision of air-displacement plethysmography and will focus primarily on papers published since 2004, with particular attention on its use in infants. Recent findings: The most significant recent findings in the air-displacement plethysmography literature are mechanistic in nature specifically dealing with measurement issues such as heat, moisture, clothing, and recently, inter-device variability. Summary: It is important to recognize that air-displacement plethysmography can be a practical instrument in the evaluation of body composition in a wide range of populations. Therefore, based on the body of literature that has emerged, air-displacement plethysmography appears to be a suitable and reliable instrument in the assessment of body composition. Of particular interest is its use in pediatric and obese individuals, areas requiring further study. Research is also needed to help us better understand sources of measurement error.
KW - Bod Pod
KW - Body composition
KW - Infants
KW - Pea Pod
UR - http://www.scopus.com/inward/record.url?scp=27744519492&partnerID=8YFLogxK
U2 - 10.1097/01.mco.0000171127.44525.07
DO - 10.1097/01.mco.0000171127.44525.07
M3 - Review article
C2 - 16205463
AN - SCOPUS:27744519492
SN - 1363-1950
VL - 8
SP - 624
EP - 629
JO - Current Opinion in Clinical Nutrition and Metabolic Care
JF - Current Opinion in Clinical Nutrition and Metabolic Care
IS - 6
ER -