Abstract
Increasing power densities and changing component design have brought about the need for accurate measurement of die junction temperature. While many different techniques exist it is difficult to compare their relative performance. To validate the accuracy of various direct and indirect test methods, the operating junction temperature of board-mounted SO16 and PQFP160 devices has been recorded using standard thermal test die. Numerical analysis was also used to predict junction temperature and package temperature gradients. The performance of each technique is evaluated for accuracy, ease of use and relevance to real applications.
| Original language | English |
|---|---|
| Pages | 233-238 |
| Number of pages | 6 |
| Publication status | Published - 1998 |
| Externally published | Yes |
| Event | Proceedings of the 1998 4th International Workshop on Thermal Investigations of ICs Microstructures - Cannes, Fr Duration: 27 Sep 1998 → 29 Sep 1998 |
Conference
| Conference | Proceedings of the 1998 4th International Workshop on Thermal Investigations of ICs Microstructures |
|---|---|
| City | Cannes, Fr |
| Period | 27/09/98 → 29/09/98 |