Effect of thermosonication, pulsed electric field and their combination on inactivation of Listeria innocua in milk

F. Noci, M. Walkling-Ribeiro, D. A. Cronin, D. J. Morgan, J. G. Lyng

Research output: Contribution to journalArticlepeer-review

91 Citations (Scopus)

Abstract

The impact of thermosonication (TS) and pulsed electric field (PEF), individually and combined, on the survival of Listeria innocua 11288 (NCTC) in milk was investigated. TS (400 W, 160 s) without pre-heating reduced L. innocua by 1.2 log10 cfu mL-1, while shorter treatment times produced negligible inactivation, suggesting TS to be a hurdle rather than an effective standalone treatment. PEF (30 and 40 kV cm-1, 50 μs) at 10 °C caused a reduction of L. innocua of 1.1 and 3.3 log cycles, respectively. The highest field strength (40 kV cm-1) combined with TS (80 s) led to 6.8 log10 cfu mL-1 inactivation. Milk pre-heated to 55 °C (over 60 s) prior to TS followed by PEF (30 and 40 kV cm-1) showed inactivation between 4.5 and 6.9 log10 cfu mL-1, the latter being comparable (P > 0.05) with thermal pasteurisation. The data indicate that TS followed by PEF represents a valid alternative for L. innocua inactivation in milk.

Original languageEnglish
Pages (from-to)30-35
Number of pages6
JournalInternational Dairy Journal
Volume19
Issue number1
DOIs
Publication statusPublished - Jan 2009
Externally publishedYes

Fingerprint

Dive into the research topics of 'Effect of thermosonication, pulsed electric field and their combination on inactivation of Listeria innocua in milk'. Together they form a unique fingerprint.

Cite this