T1 - External stability of reinforced soil walls
AU - Naughton, P.
AU - Scotto, M.
AU - Rimoldi, P.
AU - Vicari, M.
PY - 2013
Y1 - 2013
N2 - The external stability; forward sliding, overturning and rotation stability, of reinforced soil walls was assessed using Eurocode 7 and BS 8006 (1995). Overall Eurocode 7 gave higher utilisation factors than BS 8006 (1995). Eurocode 7 Design Approaches 1 (Combination 2) and 3 were found to be critical, and for the structures analysed, always gave the highest utilisation factors. In sliding, Design Approach 3 required a foundation soil with an increased angle of friction or longer reinforcement to maintain stability. The material factor of 1.25 applied to the tangent of the angle of friction in Design Approaches 1 (Combination 2) and 3 had a significant effect on stability, increasing the utilisation factor. The eccentricity of the resultant vertical load varied significantly, with no agreement between values determined using Eurocode 7 and BS 8006 (1995). The design of walls in German (EBGEO, 2010) and France (NF P94-270, 2009) in accordance with Eurocode 7 was found to be more conservative (higher utilisation factors) than walls designed using BS 8006 (1995).
AB - The external stability; forward sliding, overturning and rotation stability, of reinforced soil walls was assessed using Eurocode 7 and BS 8006 (1995). Overall Eurocode 7 gave higher utilisation factors than BS 8006 (1995). Eurocode 7 Design Approaches 1 (Combination 2) and 3 were found to be critical, and for the structures analysed, always gave the highest utilisation factors. In sliding, Design Approach 3 required a foundation soil with an increased angle of friction or longer reinforcement to maintain stability. The material factor of 1.25 applied to the tangent of the angle of friction in Design Approaches 1 (Combination 2) and 3 had a significant effect on stability, increasing the utilisation factor. The eccentricity of the resultant vertical load varied significantly, with no agreement between values determined using Eurocode 7 and BS 8006 (1995). The design of walls in German (EBGEO, 2010) and France (NF P94-270, 2009) in accordance with Eurocode 7 was found to be more conservative (higher utilisation factors) than walls designed using BS 8006 (1995).
UR - http://www.scopus.com/inward/record.url?scp=84960968538&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84960968538
T3 - Design and Practice of Geosynthetic-Reinforced Soil Structures
SP - 223
EP - 232
BT - Design and Practice of Geosynthetic-Reinforced Soil Structures
A2 - Gottardi, Guido
A2 - Cazzuffi, Daniele
A2 - Ling, Hoe I.
A2 - Han, Jie
A2 - Tatsuoka, Fumio
PB - DEStech Publications Inc.
T2 - International Symposium on Design and Practice of Geosynthetic-Reinforced Soil Structures and Joint Sessions with 26th Italian National Conference on Geosynthetics
Y2 - 14 October 2013 through 16 October 2013
ER -