TY - JOUR
T1 - Methodological Considerations for a Vascular Function Test Battery
AU - Kimble, Rachel
AU - Keane, Karen M.
AU - Lodge, John K.
AU - Howatson, Glyn
N1 - Publisher Copyright:
© Georg Thieme Verlag KG Stuttgart. New York.
PY - 2019
Y1 - 2019
N2 - There is a dearth of information regarding the reliability of non-invasive measures of vascular function taken in a single testing session. This study aimed to determine the test-retest reliability of a test battery of vascular function measures: automated blood pressure (BP), laser Doppler imaging with iontophoresis (LDI), digital volume pulse (DVP), pulse wave velocity (PWV), augmentation index (AIx) measured by pulse wave analysis (PWA) and flow-mediated dilation (FMD) taken within and between sessions. Measures were taken in 21 non-smoking males intra-session and again inter-session (one week apart) to determine repeatability and reproducibility, respectively. There was moderate to excellent repeatability (ICC: 0.53-0.93; CV=2.2-18.1%) and reproducibility (ICC: 0.71-0.96; CV 1.9-14.2%) for BP, DVP stiffness index, PWV, AIx, AIx normalised to heart rate (75 bpm), absolute and percentage FMD. Repeatability of the DVP reflection index was moderate (ICC: 0.64; CV=9.5%) but there was poor reproducibility (ICC: 0.17; CV=15.1%). Moreover, the repeatability and reproducibility of the LDI measures ranged from poor to good (ICC: 0.31-0.84; CV=28.4-36.7%). These data indicated that there was considerable variability in the repeatability and reproducibility of measurements of endothelial function and arterial stiffness taken in a battery of measurements, which needs careful consideration in future research designs.
AB - There is a dearth of information regarding the reliability of non-invasive measures of vascular function taken in a single testing session. This study aimed to determine the test-retest reliability of a test battery of vascular function measures: automated blood pressure (BP), laser Doppler imaging with iontophoresis (LDI), digital volume pulse (DVP), pulse wave velocity (PWV), augmentation index (AIx) measured by pulse wave analysis (PWA) and flow-mediated dilation (FMD) taken within and between sessions. Measures were taken in 21 non-smoking males intra-session and again inter-session (one week apart) to determine repeatability and reproducibility, respectively. There was moderate to excellent repeatability (ICC: 0.53-0.93; CV=2.2-18.1%) and reproducibility (ICC: 0.71-0.96; CV 1.9-14.2%) for BP, DVP stiffness index, PWV, AIx, AIx normalised to heart rate (75 bpm), absolute and percentage FMD. Repeatability of the DVP reflection index was moderate (ICC: 0.64; CV=9.5%) but there was poor reproducibility (ICC: 0.17; CV=15.1%). Moreover, the repeatability and reproducibility of the LDI measures ranged from poor to good (ICC: 0.31-0.84; CV=28.4-36.7%). These data indicated that there was considerable variability in the repeatability and reproducibility of measurements of endothelial function and arterial stiffness taken in a battery of measurements, which needs careful consideration in future research designs.
KW - arterial stiffness
KW - endothelial function
KW - repeatability
KW - reproducibility
UR - http://www.scopus.com/inward/record.url?scp=85069830984&partnerID=8YFLogxK
U2 - 10.1055/a-0946-1293
DO - 10.1055/a-0946-1293
M3 - Article
C2 - 31307097
AN - SCOPUS:85069830984
SN - 0172-4622
VL - 40
SP - 601
EP - 608
JO - International Journal of Sports Medicine
JF - International Journal of Sports Medicine
IS - 9
ER -