Reliability and validity of clinically accessible smart glove technologies to measure joint range of motion

Jeffrey Henderson, Joan Condell, James Connolly, Daniel Kelly, Kevin Curran

Research output: Contribution to journalArticlepeer-review

10 Citations (Scopus)

Abstract

Capturi ng hand motions for hand function evaluations is essential in the medical field. For many allied health professionals, measuring joint range of motion (ROM) is an important skill. While the universal goniometer (UG) is the most used clinical tool for measuring joint ROM, devel-opments in current sensor technology are providing clinicians with more measurement possibilities than ever. For rehabilitation and manual dexterity evaluations, different data gloves have been de-veloped. However, the reliability and validity of sensor technologies when used within a smart device remain somewhat unclear. This study proposes a novel electronically controlled sensor monitoring system (ECSMS) to obtain the static and dynamic parameters of various sensor technologies for both data gloves and individual sensor evaluation. Similarly, the ECSMS was designed to closely mimic a human finger joint, to have total control over the joint, and to have an exceptionally high precision. In addition, the ECSMS device can closely mimic the movements of the finger from hy-perextension to a maximum ROM beyond any person’s finger joint. Due to the modular design, the ECSMS’s sensor monitoring board is independent and extensible to include various technologies for examination. Additionally, by putting these sensory devices through multiple tests, the system accurately measures the characteristics of any rotary/linear sensor in and out of a glove. Moreover, the ECSMS tracks the movement of all types of sensors with respect to the angle values of finger joints. In order to demonstrate the effectiveness of sensory devices, the ECSMS was first validated against a recognised secondary device with an accuracy and resolution of 0.1°. Once validated, the system simultaneously determines real angles alongside the hand monitoring device or sensor. Due to its unique design, the system is independent of the gloves/sensors that were tested and can be used as a gold standard to realise more medical equipment/applications in the future. Conse-quently, this design greatly enhances testing measures within research contact and even non-con-tact systems. In conclusion, the ECSMS will benefit in the design of data glove technologies in the future because it provides crucial evidence of sensor characteristics. Similarly, this design greatly enhances the stability and maintainability of sensor assessments by eliminating unwanted errors. These findings provide ample evidence for clinicians to support the use of sensory devices that can calculate joint motion in place of goniometers.

Original languageEnglish
Article number1555
Pages (from-to)1-37
Number of pages37
JournalSensors
Volume21
Issue number5
DOIs
Publication statusPublished - 1 Mar 2021

Keywords

  • Data gloves
  • Joint measurement
  • Measurement system
  • Parkinson’s disease
  • Rehabilitation
  • Rheumatoid arthritis
  • Smart sensing
  • Stroke recovery

Fingerprint

Dive into the research topics of 'Reliability and validity of clinically accessible smart glove technologies to measure joint range of motion'. Together they form a unique fingerprint.

Cite this