T1 - The reliability of electromechanical delay and torque during isometric and concentric isokinetic contractions
AU - Howatson, Glyn
AU - Glaister, Mark
AU - Brouner, James
AU - van Someren, Ken A.
PY - 2009/10
Y1 - 2009/10
N2 - The purpose of this investigation was to examine the intra-subject reliability of electromechanical delay (EMD) and torque of the dominant and non-dominant elbow flexors during isometric and isokinetic muscle contractions repeated over five consecutive days. Eleven volunteers that were unfamiliar with isokinetic dynamometry participated in this study and were asked to attend the laboratory on five consecutive days. An isokinetic dynamometer was used to exercise the elbow flexors under isometric, slow (60° s-1) and fast (210° s-1) isokinetic conditions; surface electromyography was recorded from the belly of biceps brachii and the signal was synchronised with the dynamometer to determine EMD. Intra-subject reliability for all measures was good (CV range, 3.1-6.5%) with no discernable difference between the dominant and non-dominant arms during isometric and isokinetic conditions. In addition, there was little difference in EMD and torque variability between the dominant and non-dominant arms which may have applications for clinicians and future research design when monitoring and investigating human muscle function. These data provide researchers and clinicians with an indication of the magnitude of change that is required to elucidate the presence of a meaningful change to muscle function in the elbow flexors.
AB - The purpose of this investigation was to examine the intra-subject reliability of electromechanical delay (EMD) and torque of the dominant and non-dominant elbow flexors during isometric and isokinetic muscle contractions repeated over five consecutive days. Eleven volunteers that were unfamiliar with isokinetic dynamometry participated in this study and were asked to attend the laboratory on five consecutive days. An isokinetic dynamometer was used to exercise the elbow flexors under isometric, slow (60° s-1) and fast (210° s-1) isokinetic conditions; surface electromyography was recorded from the belly of biceps brachii and the signal was synchronised with the dynamometer to determine EMD. Intra-subject reliability for all measures was good (CV range, 3.1-6.5%) with no discernable difference between the dominant and non-dominant arms during isometric and isokinetic conditions. In addition, there was little difference in EMD and torque variability between the dominant and non-dominant arms which may have applications for clinicians and future research design when monitoring and investigating human muscle function. These data provide researchers and clinicians with an indication of the magnitude of change that is required to elucidate the presence of a meaningful change to muscle function in the elbow flexors.
KW - Coefficient of variation
KW - Electromyography
KW - Isokinetic dynamometry
KW - Repeatability
UR - https://www.scopus.com/pages/publications/68949181521
U2 - 10.1016/j.jelekin.2008.02.002
DO - 10.1016/j.jelekin.2008.02.002
M3 - Article
C2 - 18381243
AN - SCOPUS:68949181521
SN - 1050-6411
VL - 19
SP - 975
EP - 979
JO - Journal of Electromyography and Kinesiology
JF - Journal of Electromyography and Kinesiology
IS - 5
ER -